Datasheet !full! | Vlc 1600

This article provides a detailed breakdown of the , including technical specifications, features, applications, and installation details. 1. Product Overview: The Alerton VLC-1600

Compact size for tight control panel spacing: 4.9" H x 5.0" W x 1.4" D (125mm x 127mm x 36mm).

For full installation details, you can refer to the official Honeywell Building Automation product page or download the VLC-1600-E Datasheet or how to configure the VisualLogic programming for this device? hbt-bms-VLC-1600-E-datasheet.pdf vlc 1600 datasheet

Alerton BACtalk VLC-1600 is a high-performance, fully programmable BACnet-compliant field controller designed specifically for high-density input monitoring in building automation systems. It is primarily used to augment the monitoring capabilities of other controllers in a network. www.acontrols.co.za Technical Specifications The following data reflects the standard and the updated VLC-1600-E models: (Standard) VLC-1600-E (Enhanced) Motorola AZ60 www.acontrols.co.za 32-bit ARM Cortex-M4F (80 MHz) 16 High-resolution 10-bit www.acontrols.co.za 16 High-resolution 16-bit No control outputs Honeywell Building Automation No control outputs Non-volatile Flash www.acontrols.co.za 512 MB Non-volatile Flash Communication BACnet MS/TP up to 76.8 Kbps www.acontrols.co.za Communication BACnet MS/TP up to 115.2 Kbps 24 VAC @ 10 VA max www.acontrols.co.za 24 VAC, 5 VA min / 26 VA max Dimensions 125mm H x 138mm W x 36mm D www.acontrols.co.za Dimensions 125mm H x 127mm W x 36mm D Key Features and Functions Universal Inputs:

| Parameter | Test Condition | Min | Typ | Max | Unit | | :--- | :--- | :--- | :--- | :--- | :--- | | Center Wavelength | CW, Po=1600mW | 1590 | 1605 | 1620 | nm | | Spectral Width (FWHM) | - | 1.5 | 2.5 | 4.0 | nm | | Threshold Current | Ith | - | 350 | 450 | mA | | Slope Efficiency | - | 0.9 | 1.1 | 1.3 | W/A | | Forward Voltage | VF | 1.8 | 2.1 | 2.5 | V | | Monitor Current (PD) | VRPD=5V | 0.3 | 0.6 | 1.0 | mA | | Beam Divergence (Parallel) | Θ∥ | 5 | 8 | 11 | degrees | | Beam Divergence (Perpendicular) | Θ⟂ | 25 | 32 | 40 | degrees | This article provides a detailed breakdown of the

: Program data is stored in non-volatile flash memory to ensure stability during power loss.

: Seamlessly expanding network input counts when adjacent controllers run out of physical wire terminations. For full installation details, you can refer to

Complies with Subpart J, Class A parameters for commercial operation.