Dictates how many hours pass between automated defrost cycles. For standard walk-in coolers, 4 to 6 hours is typical.
| | Description | Typical Values / Notes | | :------------ | :----------------------------------------------------------------------------------------------------------- | :----------------------------------------------------------------------------------------------------------------------------------- | | SET | Regulation Setpoint. The target temperature. | Adjustable between LSE and HSE values. Usually modifiable by the end-user via Quick Menu. | | diF | Differential or hysteresis. The difference between the cut-in and cut-out temperature. | For example, a setpoint of 2°C with a diF of 2°C means the compressor turns off at 2°C and back on at 4°C. | | HSE | High Setpoint Limit. The maximum value allowed for the "SET" parameter. | Protects the system from being set too high. | | LSE | Low Setpoint Limit. The minimum value allowed for the "SET" parameter. | Protects the system from being set too low. | | Ont | Compressor ON time with faulty regulation probe. The duration the compressor runs for if the main probe fails. | A safety feature to provide some cooling even with a sensor error. | | OFt | Compressor OFF time with faulty regulation probe. The duration the compressor stays off for if the main probe fails. | Pairs with Ont to create a timed duty cycle for emergency operation. | | OdO | Output delay from power-on. A delay before any outputs (like the compressor) are activated after the controller powers on. | Prevents short cycling and voltage spikes from multiple units restarting simultaneously. | | dit | Interval between defrosts. How often a defrost cycle is initiated. | Set based on frost buildup and application requirements. | | dEt | Maximum defrost duration. The safety timer that stops a defrost if it takes too long, preventing damage. | Set a realistic duration; if the defrost stops by time-out, it may indicate a problem with the evaporator heater or sensor. |
Full support for Modbus and Televis systems for remote monitoring. 2. Key Sections of the Eliwell SB655/C Manual eliwell sb655 c manual best
Protected via a dedicated code (typically 22 ); allows technicians to alter differential bands and safety thresholds.
The is a highly advanced, universal controller designed for air conditioning and refrigeration systems with up to two circuits . As part of the prestigious Schneider Electric brand, the Eliwell Energy range provides unmatched flexibility for managing Scroll, Semi-Hermetic, or Screw compressors with up to 4 power output steps. Dictates how many hours pass between automated defrost
is a highly versatile, compact HVAC parametric controller optimized for centralized air-conditioning units, chillers, and heat pumps. Managing this dual-circuit device efficiently requires a precise understanding of its programming matrix, wiring schematics, and alarm structures.
The Eliwell SB655 C is a powerhouse in the world of HVAC and refrigeration control. Part of the renowned Energy Flex series, this universal controller is designed to manage complex systems like air conditioning units, chillers, heat pumps, and even panel-mounted fermentation applications with two circuits. However, unlocking its full potential requires a deep understanding of its manual, programming, and operational best practices. The target temperature
: 5 Built-in SPST relays for compressors, fans, or water pumps. Analog Outputs : 2 Pulse-Width Modulation (PWM) and two outputs for variable frequency inverter drives.
The SB655C controller is designed for energy flexibility. Through careful use of inputs and configuration, you can implement , where the system reduces its power consumption when an external signal (like a utility peak pricing signal) is received. Economy modes can also be configured to run the system at different setpoints based on occupancy or time of day, as managed via the digital inputs.